Vacuum Insulated Transfer Systems

Vacuum-Jacketed Pipe and Flexible Lines

Rigid (VIP) and flexible (VIF) vacuum insulated lines that carry cryogenic liquids such as LN2, LOX, LAr, LNG and LCO₂ from the tank to the point of use with minimal heat loss: project-specific design, fabrication with our manufacturing partners, site installation and testing.

Request a quote and technical sheetor call: Marmara & Aegean +90 533 300 63 67 · Anatolia +90 536 433 56 44

Minimal heat lossStatic high vacuum and multi-layer insulation (MLI) keep heat gain very low; for example, about 0.9 W/m on a DN25 line.
No frosting or drippingThe outer jacket stays at ambient temperature, so no ice, condensation or slippery floors form along the line.
Liquid quality preservedLess vaporization along the line means more liquid and more stable pressure at the point of use.
Site installation of a vacuum-jacketed cryogenic pipeline
Site installation: vacuum-jacketed line from tank outlet to plant
Vacuum-jacketed pipelines on site
VIP lines on site
Vacuum level measurement on a vacuum-jacketed line
Vacuum measurement: 0.009 mbar

Product range

Rigid vacuum-jacketed pipe (VIP)

  • Spools from Ø12 to DN200
  • Straight and field-fit spools, 45°/90°/custom bends
  • Equal and reducing tees, expansion loops and bellows
  • Valve boxes and instrument branches

Vacuum insulated flexible line (VIF)

  • Where rigid spools are not feasible or for moving connections
  • Corrugated stainless inner and outer hose, steel braiding, MLI
  • Options with single bend radius from 150 mm
  • Mobile tank and bulk tank filling, connection to vibrating equipment

Connection types

  • Bayonet coupling: fast, weld-free assembly and disassembly
  • Welded coupling (vacuum or perlite): joined by welding on site
  • Flexible line ends: weld-on, UNF fitting, nipple, 3-piece union, filling lance
  • Universal end: weld prep for any fitting

Main dimensions and performance

SizeInner pipe (Ø × t)Outer jacket (Ø × t)Heat loss (W/m)Capacity (L/h)¹
Ø1212 × 1 mm33.4 × 1.65 mm0.5245
DN1521.3 × 1 mm60.3 × 2.7 mm0.61,169
DN2533.4 × 2 mm76.1 × 3.05 mm0.92,288
DN4048.3 × 2.7 mm88.9 × 3.05 mm1.15,004
DN5060.3 × 2.7 mm114.3 × 3.05 mm1.48,020
DN6576.1 × 3.05 mm133 × 3 mm1.612,787
DN8088.9 × 3.05 mm141.3 × 3.4 mm1.817,731
DN100114.3 × 3.05 mm168.3 × 3.4 mm2.226,760
DN150168.3 × 3.4 mm219.1 × 3.7 mm3.264,796
DN200219.1 × 3.7 mm273.1 × 4.19 mm3.899,737

¹ Based on saturated boiling liquid at 1 m/s. Calculations assume an ambient temperature of 20 °C. Flexible (VIF) versions are produced to order across this range. Other sizes and pressure classes on request.

Design, materials and testing

Standards
PED compliant · AD2000 / EN 13480 / ASME B31.3 (others on request)
Insulation
Static high vacuum with MLI (≤10⁻⁴ mbar)
Design temperature
−196 °C / +80 °C
Process pipe
1.4301 / 1.4306 / 1.4307 (≈304 / 304L)
Vacuum jacket
1.4301 / 1.4307, optional 1.4404 (≈316L)
Strength
Dimensional check and pressure test
NDT
Radiography (RT) or penetrant testing (PT), visual inspection
Leak tightness
Helium leak test, < 1×10⁻⁹ mbar·L/s

Maintenance and vacuum restoration

As vacuum degrades over time, heat loss rises and the jacket surface starts sweating and frosting. We measure the vacuum level of existing lines and, where needed, re-evacuate them to restore performance.

Applications

  • Hospital and laboratory LN2 lines
  • Cryobanks and biobanks
  • Industrial gas filling plants
  • Food freezing and chilling
  • LNG and LCO₂ facilities
  • Test and R&D facilities

Let’s design your line together

Share the fluid, flow rate, routing and points of use; we will come back with a technical sheet and a quotation. You can also reach us by phone or WhatsApp.









    Related articles
    Vakum ceketli kriyojenik boru hattı montajı

    Cryonos: Thermal and Cryogenic Engineering

    CONTACT

    Konutkent Mah. 3035. Cadde No:74 SUİT TOWER A Blok No:12 Çankaya/ANKARA/TURKEY

    +90 (312) 395 55 03 (Head Office)

    +90 (533) 300 63 67 (Marmara & Aegean)

    WhatsApp · Marmara & Aegean

    +90 (536) 433 56 44 (Anatolia)

    WhatsApp · Anatolia

    info@cryonos.com